Enteral Feeding Medical Infusion Pump Medical Nutrition Delivery System Precision Flow Control and Alarm Safety Features for Hospital Clinical Home Care Patient

Still deciding? Get samples of $ !
Request Sample

Product Description

📋 Basic Info.
Model NO.
NP-100
Certification
CE
Group
All People
Features
Four Infusion Modes
Supports Infusion
Preset Range 0ml-9999ml
Infusion Error
Average ±5%
Rapid Rate
100 to 1200 Ml/H
Origin
China
HS Code
9018909090
🔍 Product Description
Product Image
Feeding Pump Details
It features a swallowing mode and a swallowing sequence mode. With precise infusion, it provides worry-free nutrition and real-time display functions. It can display various infusion statuses and cumulative amounts in sync. It also boasts a system self-checking function and a pressure release function. It can be combined with infusion pumps, injection pumps, and target-controlled pumps of the same series to form an infusion workstation. It can store over 2000 historical records.
🖼️ Detailed Photos
Main View
Detail 1
Detail 2
Detail 3
Detail 4
📊 Product Parameters
Specs
Parameter Name Specifications
Infusion error Average flow rate error ±5%, swallow mode pill dose error ±5%
Infusion mode & speed Constant flow 1.0 mL/h to 1200 mL/h (step 0.1 mL/h)
Swallowing mode 1.0mL/h-1100mL/h (step 0.1mL/h)
Sequence mode Up to 24 preset rates, continuous running
Swallow sequence Up to 24 sets, volume/time automatically calculated
Rapid injection/irrigation 100 mL/h to 1200 mL/h (100 mL/h increments)
Heating range 30℃ to 39℃ (error ±2℃)
Safety Class Class I CF-type (Highest safety rating)
🚀 Main Products
Frequently Asked Questions
What is the primary function of the NP-100 device?
It is a medical infusion system designed for enteral feeding, featuring precise flow control, swallowing modes, and safety alarms for clinical and home care.
What kind of infusion modes does it support?
The system supports Constant Rate Mode, Swallow Mode, Constant Flow Sequence Mode, and Swallowing Sequence Mode for varied medical needs.
What safety features are included in this system?
It features a Class I CF-type safety rating, system self-checking functions, pressure release functions, and blocking alarm thresholds (high, medium, low).
Does the system provide temperature control for infusions?
Yes, it includes an adjustable infusion heating range from 30℃ to 39℃ with 1℃ increments and a safety error margin of ±2℃.
What are the accepted payment and delivery terms?
Accepted payment methods include T/T and D/P. International delivery terms offered include FOB, CFR, CIF, EXW, FAS, CIP, FCA, CPT, and DDP.
Can historical data be recorded on the device?
Yes, the device is capable of storing over 2000 historical records for medical review and monitoring.